1250 Poydras Buiding Statistics

1250 Poydras Street 
New Orleans, LA 70113 
Phone: 504.522.253

Gross sf: 476.130
Rentable sf: 422.890

PHYSICAL ANALYSIS    
Bldg Ht   342’
Number of Floors   24
Number of Elevators   13
Window Modules   6’2x 4’9
Ceiling Grid   2’x2’
Flr to Ceiling Ht   8’9”  
Flr to Window Ht   7’
Flr to Flr Ht   12’9”
Flr to Beam Ht   11’
Bay Depth   34’6” 
Interior Columns   0

FINISHES
Exterior Walls: Bronze Tone Aluminum
Windows: Solar Ban bronze tone double paned glass
Spandrel: Blk non-solar insulated

Interior Main Lobby/Entrance
Walls: Marble
Floors: Marble
Accents: Chrome
Ceiling: Suspended Sheetrock
                2’X2’ lay-ins
Lighting: Incandescent
Ent Door: Double w/ revolving

Elevators
Finishes: 30 oz carpet accented lay-ins

Elevator Lobbies 
Walls: Travertine
Floors: 30 oz. carpet w/borders

Tenant Corridors
Walls: Sheetrock VWC
Ceilings: 2'X2' lay-ins
Lighting: 18 cell parabolic

Restrooms
Walk Sheetrock VWC
Ceilings: Sheetrock
Lighting: Fluorescent
Floors: tile
Fixtures: Standard handicap
Accessible, porcelain

Stairwells
Stairs: Standard Metal
Walls: Sheetrock, 2 hr fire rated
Lighting: Fluorescent,
battery back up

Tenant Finishes
Walls: Sheetrock VWC
Floors: 30 oz. carpet
Ceilings: 2' X 2' lay-ins
Doors: 36" X 8'6" mahogany
solid core
Lighting: Parabolic fixtures

LIFE SAFTEY SYSTEMS
Fully sprinklered
Smoke detectors in public areas
Stairwell pressurization
Emergency lights
Electric fire pump
450 KW emergency generators
Fire standpipe (2-6") risen
Fire command station (1st flr)
Annunciator system
Fire alarm system installed
per NFPA code

ELEVATORS
Number: 13
Type: Otis
Number                    Floors                       Speed
4 Low Rise                   2-10                         350 fpm
4 Mid Rise                    2, 11-20                 700 fpm
3 High Rise                   2, 21-24                   700 fpm
1 Freight                      1-24                      350fpm
1 Handicapped              1-2                           90 fpm

Emergency Power Operation:
1 elevator per bank

Freight Elevators

Capacity: 3,500 lbs
Platform Size: 6'5" X 5’ X 9'11" Ht
Door Opening: 3'6 X 8'6"
Type: Otis

Back to Poydras Building Page

SECURITY

Card access
After hours security patrol
Surveillance camera system

HVAC
Description of System:
1,300 ton chilled water
closed loop system

Chillers: 2 - 650 ton Yorks
Carrier: AHU’s: 1flr./24 units

Air Distribution per Floor:
VAV Zone system
12 exterior zones
4 interior Zones, 1 thermostat zone to control 
cooling and heating

Heating: Electric resistance heat

Outside Air: 1,000 cfm/floor

Design Conditions
Summer
Outside: DB 91<F, WB 80<F
Inside: DB 75<F, WB 50<F

Winter
Outside: DB 32<F
Inside: DB 75<F

PLUMBING
Dual domestic water pumps
Electric Water heaters (restrooms only)
Waste, vent and water risers
Roof drain system

ELECTRICAL
Main electrical power is fed from 2
sub-stations with auto transfer switch

Description

Building Power: 480V/ 277V
Available: 208/ 110V
Chiller Power: 4,160V
Emergency Power: 480V/ 277V

DESIGN LIVE LOADS

Live Load Roof 30 lbs PSF
Live Load Floor*: 75 lbs PSF
Partition: 10 lbs PSF
Mechanical Room: 150 lbs PSF
Dead Load Floor: 87 lbs PSF
Dead Load Room: 109 lbs PSF

*Certain areas have live load in excess of design

Poydras Properties, LLC

Located near the Superdome and just blocks from the heart of the Central Business District

Poydras Properties, LLC


Get In Contact


Phone: 504.522.2535

1250 Poydras Street, Suite 220
New Orleans, LA 70113
 

Properties

1250 Poydras

1250 Poydras Street
New Orleans, LA 70113
Phone: 504.522.2535

Entergy Corporation Building

639 Loyola Avenue
New Orleans, LA 70113
Phone: 504.522.2535